Customization: | Available |
---|---|
Application Fields: | New Energy |
Certification: | Test Report |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
(Nm³/ h) H2 CAPACITY |
(Nm³/ h) O2 CAPACITY |
H2 PURITY |
(A) CURRENT |
(V)DC VOLTAGE |
Electrolysis WORKING TEMPERATURE |
TOTAL WATER CONSUMPTION |
COOLING WATER CONSUMPTION |
SHH-10 | 10 | 5 | 99.999% | 1000 | 54 | ≤85ºC | 10L/h | 2m³/ h |
SHH-20 | 20 | 10 | 99.999% | 1000 | 105 | ≤85ºC | 20L/h | 4m³/ h |
SHH-50 | 50 | 25 | 99.999% | 1000 | 265 | ≤85ºC | 50L/h | 10m³/ h |
SHH-100 | 100 | 50 | 99.999% | 3000 | 176 | ≤85ºC | 100L/h | 20m³/ h |
SHH-200 | 200 | 100 | 99.999% | 3000 | 352 | ≤85ºC | 200L/h | 40m³/ h |
SHH-300 | 300 | 150 | 99.999% | 3000 | 528 | ≤85ºC | 300L/h | 60m³/ h |
SHH-400 | 400 | 200 | 99.999% | 3000 | 700 | ≤85ºC | 400L/h | 80m³/ h |
SHH-500 | 500 | 250 | 99.999% | 8050 | 328 | ≤85ºC | 500L/h | 100m³/ h |
SHH-600 | 600 | 300 | 99.999% | 8050 | 390 | ≤85ºC | 600L/h | 120m³/ h |
SHH-700 | 700 | 350 | 99.999% | 8050 | 457 | ≤85ºC | 700L/h | 140m³/ h |
SHH-800 | 800 | 400 | 99.999% | 8050 | 524 | ≤85ºC | 800L/h | 160m³/ h |
SHH-900 | 900 | 450 | 99.999% | 8050 | 588 | ≤85ºC | 900L/h | 180m³/ h |
SHH-1000 | 1000 | 500 | 99.999% | 8050 | 653 | ≤85ºC | 1000L/h | 200m³/ h |