Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF

Product Details
Customization: Available
Type: Power
Structure: Fixed Board
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
76
Year of Establishment
2002-06-24
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
  • Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
Find Similar Products

Basic Info.

Model NO.
suar
Form
All- packaged Type
Operation Voltage
Low Voltage
Size
1 Uint
Application Range
High-rise Buildings
Shell Material
Steel Plate
Shell Protection Grade
IP30
Brand
Sanhe
Transport Package
Plywood Carton
Specification
35kvar
Trademark
sanhe
Origin
Shenzhen
HS Code
8543709990
Production Capacity
5000

Product Description

SUAR realize the balanced three phase through step-by-step work,first the current transformer real-time monitoring of the load side of the current, and DSP processing and analysis of this data and calculation of equilibrium required for each phase of the compensation current, then drive the IGBT output, to achieve the object.

Feature:

Main power module inverter adopts international famous brand IGBT devices;

A variety of control modes can be set freely according to demand;

With full protection features including overload, overcurrent, short circuit, the system starts with self-diagnostic function;

Start with a buffer control circuit can be avoided from the start instant excessive input current ;

Divided with independent control, both to balance the load current, but also to achieve single-phase, three-phase reactive power compensation;

Built-in wireless communication module, can achieve remote monitoring and data acquisition;

Device uses the column installation, commissioning maintenance is simple, easy to transport.

citor compensation scheme, it is precise, two-way, fast reactive power compensation capabilities, and to eliminate the risk of capacitive system harmonics; Compared with the traditional SVG program, it can resolve the problem of harmonic and reactive power. It is equipped with high quality power factor controller SGC .
     The Wall Mounted type is preferred to be used in equipment improvement which is very conveninet to install. It can be used to filter harmonics.
 -phone APP operation to run or stop,set parameters or check data
- the 3-Level Topology Design Approach 
- step-less reactive power compensation for inductive and capacitor loads.   
- Optimal solution to reactive compensation and three-phase unbalanced compensation
- Integrating general LC compensation with the latest SVG compensation technology
- Integrated Control & Monitoring System (ICMS)with 18 I/O ports to implementflexibleLC and SVG applications
-PF= 0.99, avoiding over-compensation and under-compensation
-Ultra-compact, space economical / User-friendly, ease of commissioning / Parallel capability 
-Available in rack, wall mounting designs and complete enclosure type 
 
 


Parameter:
Model No# SUAR-0.4/50 SUAR-0.4/75 SUAR-0.4/100
System
Nominal Voltage 380V
Input phase voltage range 80%~120%
Power Grid Frequency 50Hz
Efficiency >97.5%
Wiring 3P3W/3P4W
topology 3 level topology
Parameter
Compensation Unbalance <5%
Nominal Current 50A 75A 100A
Reactive power Compensation Output Capacitive or inductive output
Reactive power Compensation Capacity 35kvar 50kvar 70kvar
Reactive power Compensation Rate >99%
Response <15ms
Protection Function Output over-current, over-voltage power grid, the system over-temperature, wrong sequence,
Resonance protection, synchronization failure, frequency deviation, short circuit protection
Telecommunication
Telecom.Sort RS485/Ethernet/WIFI
Telecom.Contract Modbus
Mechanical
Size 692×587×1160(mm)
(W×D×H)
692×587×1160(mm)
(W×D×H)
692×587×1160(mm)
(W×D×H)
Color Stainless Steel
Weight 60kg 70kg 100kg
Installation Outdoor
Environmental
Working Temp. -20 ºC  ~  +50 ºC
Altitude <1500m
IP class IP44



Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF

Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF
Automatic Reactive Power Compensation and Harmonic Filtering Device with Cables PF




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier