Dynamic Voltage Regulator (AVC) is a device that manages voltage quality problems such as voltage fluctuations in the three-phase power grid and low power factor in the distribution network.
The whole machine of the dynamic voltage regulator (AVC) is connected in series to the outlet of the distribution transformer through the coupling transformer system side, with full automatic control, real-time detection of grid voltage data, and comparison with the set output voltage. The voltage to be compensated is flexibly controlled through the converter part, with bidirectional adjustment, flexible setting of output voltage, and a large adjustment range. The inverter output voltage is coupled to the system side through the coupling transformer, and after superimposed with the system voltage, the purpose of compensating the voltage is achieved; that is, only the difference part needs to be compensated to achieve the minimum compensation power.
Feature
Diagram
Model Selection
Rated capacity (KVA) | 100 | 150 | 200 | 300 | 400 | 500 | 600 |
Dimensions (D*W*H) mm | 600*700*1600 | 800*800*1800 | 1000*800*2000 | 1200*1000*2000 | |||
weight (Kg) | 360 | 420 | 580 | 780 | 1050 | 1220 | 1320 |
Control method | Dual DSP full digital control realizes the full digitalization of IGBT rectification and inverter converter , the latest IGBT rectification technology, low harmonic current, green environmental protection, high efficiency and energy saving. | ||||||
How it works | AVC is composed of rectifier, inverter, compensating isolation transformer and bypass. When the grid voltage deviates from the set value, the dynamic voltage regulator (AVC) supplies power to the load in different ways according to the depth of grid drop. It controls the output of the power module on the PWM inverter side and then adds appropriate compensation voltage to the main circuit through the series coupling transformer to quickly adjust the load voltage to the rated value. The voltage sag compensation depth of 40% is completely corrected, thereby eliminating the impact of the voltage sag from the grid input end on the load. | ||||||
Circuit topology | Three-level | ||||||
Voltage regulation method | Three-phase independent regulation | ||||||
Compensation response time | < 100us | ||||||
Total response time | Full response time < 2 ms | ||||||
Input indicators | |||||||
Phase | Three-phase+N+G | ||||||
Nominal voltage | 380VAC -40 % , +30 %, (380VAC +-15 % customization) | ||||||
Nominal frequency | 47.5Hz~52.5Hz | ||||||
Output indicators | |||||||
Phase | Three-phase+N+G | ||||||
Nominal voltage | 380VAC±1% (steady-state load), 380VAC±3% (load fluctuation) | ||||||
Regulator accuracy | 380VAC± 1 % | ||||||
Output voltage total distortion rate | < 3% | ||||||
Overall efficiency | >98.5% | ||||||
Voltage correction capability | Rated power, three-phase voltage residual 80 % ~ 120 %, output voltage correction to 100%, continuous compensation | ||||||
Rated power, three-phase voltage residual 60 % ~ 130 %, output voltage correction to 100%, continuous compensation | |||||||
Rated power, three-phase voltage residual 50%, output voltage correction to 9 0%, continuous compensation 30s | |||||||
Rated power, three-phase voltage residual 40 %, output voltage correction to 70 %, continuous compensation 1s | |||||||
Rated power, three-phase voltage residual 40 %, output voltage correction to 70 % | |||||||
Reactive power compensation function | Supports functions such as high residual energy , low voltage quality problem management, reactive power compensation, etc. | ||||||
Phase Angle Error Correction | optional | ||||||
Grid voltage unbalance correction | optional | ||||||
Harmonic filtering | optional | ||||||
Grid voltage harmonic correction | Can suppress voltage harmonics below 25th order | ||||||
Bypass function | Automatic bypass/manual bypass (automatic bypass main circuit does not stop flow) | ||||||
Conversion time | Regulated voltage to bypass / bypass to regulated voltage 0ms | ||||||
HMI | |||||||
7-inch full-color touch screen | Running status, main circuit wiring diagram, running status, fault status, operation records, etc. Input and output voltage, input and output current, power factor, apparent power,active power, reactive power, frequency, temperature, operation record |
||||||
Event logging and data logging | It has 100 event records , 100 alarm records , 100 operation records , 100 historical event queries , sag curve effective value recording, non-sinusoidal instantaneous value recording , sag log display | ||||||
System Structure | |||||||
Modular design | Easy maintenance, effectively reducing the workload of operation and maintenance personnel, reducing operation and maintenance costs, and improving work efficiency | ||||||
efficiency | >98.5% | ||||||
Communication interface | RS485, Ethernet port | ||||||
Communication Protocol | Modbus protocol, TCP/IP protocol | ||||||
Environmental indicators | |||||||
Operating temperature | -10ºC~+40ºC | ||||||
Relative humidity | 0~90% non-condensing | ||||||
Storage temperature | Minimum -20ºC, maximum 70ºC; | ||||||
Operating height | <2000m, above 1500m, use the derated rating according to GB/T3859.2, and derate by 2% for every 100m increase | ||||||
Cooling method | Forced ventilation (temperature controlled) | ||||||
noise | <65 | ||||||
maintain | Front and rear maintenance | ||||||
Protection level | IP21 Other levels can be customized | ||||||
color | Black or off-white | ||||||
Note: Specifications are subject to change without prior notice. Pictures are for reference only. Please refer to the actual product. |
Standard
GB/T 18481 "Power Quality Temporary Overvoltage and Transient Overvoltage"
GB/T 30137 "Power Quality Voltage Dips and Short
Interruptions"
DL/T 1194 "Power Quality Terminology"
IEC 61000-6-2
IEC 61000-4-34
Application Fields:
Precision manufacturing(Robots production)
Hospital (MRI, PET, CT, e.g.)
Non-stop processes (Fiber production)
Buildings (UV-lamps, microwaves,Compressors )
Universities (Supercomputers, R&D TV, audio, universities, e.g.)
......