Customization: | Available |
---|---|
Type: | Power |
Structure: | Protection |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ASVGM Static Var Generator is used as comprehensive power quality improvement for power distribution system transformers side, which have the functions of power compensation, harmonic control and three phase unbalance governance simultaneously. Compared with conventional capacitor compensation scheme, it is precise, two-way, fast reactive power compensation capabilities, and to eliminate the risk of capacitive system harmonics;
Main Parameter:
Rated Voltage:0.4kV,0.48kV,0.55kV,0.69kV
Frequency:60/50Hz+/-5%
Efficiency:>=98%
Response Time:<5ms
Telecom. Port:RS485,wifi,relay-module(customized)
Telecom Protocal:Modbus
Protection Grade:IP20
Noise:<60db(beyond 2meter)
Heat dissipation:Air cooling
Main functions
maintain receiving end voltage, strengthen system voltage stability
compensate system reactive power, improve power factor, reduce line loss, save energy and reduce cost
suppress voltage fluctuation and flicker
suppress three phase unbalance
compensate both inductive and capacitive loads to achieve PF0.99 and avoid less and over compensation
Fast Response :
Fast response is implemented by SVG modules.The SVGs in the SVGC show the advantage of the electronic power switch. In the legacy SVC, the thyristor only serves as a fast switch, but cannot implement high-frequency
Optimal solution to reactive compensation and three-phase unbalanced compensation
Integrating general LC compensation with the latest SVG compensation technology
Integrated Control & Monitoring System (ICMS)with 18 I/O ports to implement flexible LC and SVG applications
PF= 0.99, avoiding over-compensation and under-compensation
Technical advantages
(1)faster response speed
(2)stronger voltage flicker suppress ability
(3)wider operating range
(4)diversified compensation function
(5)excellent harmonic output characteristic
(6)Modular design method
Application:
Hotel,Car park, Car charger station,Car 4S store etc
Specification
Model | Output Current (kVAR) |
Electrical Wiring |
Net Weight(kg) | Structure |
SVGM0.4-35/3(4)a | 35 | 3 phase,3 wires/3 phase,4 wires | 40 | Wall Mounted |
SVGM0.4-50/3(4)a | 50 | 3 phase,3 wires/3 phase,4 wires | 40 | |
SVGM0.4-60/3(4)a | 75 | 3 phase,3 wires/3 phase,4 wires | 45 | |
SVGM0.4-100/3(4)a | 100 | 3 phase,3 wires/3 phase,4 wires | 48 | |
SVGM0.4-35/3(4)b | 35 | 3 phase,3 wires/3 phase,4 wires | 40 | Rack Type |
SVGM0.4-50/3(4)b | 50 | 3 phase,3 wires/3 phase,4 wires | 40 | |
SVGM0.4-60/3(4)b | 75 | 3 phase,3 wires/3 phase,4 wires | 45 | |
SVGM0.4-100/3(4)b | 100 | 3 phase,3 wires/3 phase,4 wires | 48 |
FAQ
A:
1.External current transformer(CT)could detect real-time load current .
2.Internal DSP calculates and analyzes the reactive power content of the system.
3.Control PWM to send signal to IGBT to generate reactive power compensation current for power factor compensation.
Please specify the SVG rated voltage,frequency ,3p3w/3p4w,rated capacity,CT sampling position(grid or load side).
A: 1*manual(or electronic manual)
1*protection cover(only for wall mounted type,1 module 1 cover)
1. the standard package is not packed with breaker and current transformer. If need,please advise while ordering.
2.We recommended open-type current transformer for easy installation. open-type current transformer
3.SVG /SVG module should be protected by superior breaker. If the breaker is not installed,it is not convenient and protective for debug etc.
Production Line