• Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device
  • Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device
  • Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device
  • Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device
  • Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device
  • Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device

Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device

Certification: ISO9001, CCC, Type Test
Protection: IP 20
Installation: Indoor
Housing: Aluminum Zinc Steel
Rated Voltage: 400V
Transport Package: Plywood
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LIMC
Specification
100-20000kvar
Trademark
Sanhe
Origin
China
HS Code
8537209000
Production Capacity
10000PCS\Year

Product Description

LIMC
Series Smart Low Voltage Filter and Reactive Power Compensation Device
Rated Voltage:
Rated Frequency: 50/60HZ
Function:It can filter specific characteristic harmonics and several multiple high harmonics filter, at the same time to achieve stepless compensation, compensation without blind area, high power factor, small fluctuation range.
Application:Data centers, large performance venues, hospitals, non-ferrous metals, metallurgy, government schools and other industrial venues.
Installation:indoor\outdoor
Limc Series Smart Low Voltage Filter and Reactive Power Compensation Device

Product feature
Intelligent monitoring system:Control the working mode and cooperative compensation of APFM, SVGM and TSC, automatically adjust the output capacity, ensure that the power factor can reach 0.99 and the best filter effect.

Real-time monitoring of all parts of the system data: system data, grid data, SVG data, CT data, capacitor data and power quality, mainly including harmonics, voltage deviation, three-phase unbalance, fault records, etc.

Automatic operation, can operate by itself, clear the fault, adapt to the complex site conditions.

Monitor the working state of each capacitor, including the remaining capacity value, to minimize the switching times of TSC compensation and the average input time of  TSC compensation, thus greatly extending the service life of the equipment.

RS485 communication and Ethernet communication can be realized, the device also accept remote control operation.
Typical Application

 
Industry category Industrial characteristics Applied analysis
Commercial centers, automobile manufacturing,ports, etc load change and three-phase unbalance degree are relatively much more 1. Reactive power required by quick compensation system; 2, can quickly solve the system needs
unbalanced reactive power, etc.;

Data centers, large performance    venues, hospitals, nonferrous metals,
metallurgy,government schools, etc
The harmonic content is rich while the           anti-harmonic ability is poor, the traditional passive
filtering compensation  is not effective, and the power quality is sensitive

1. Reactive power required by quick compensation system; 2, fast real-time dynamic filter unless linear
load generated harmonics

Other industries

The traditional passive filter       compensation device is widely used
1. Solve the blind area of traditional reactive
power compensation;
2.Can filter out the low harmonic;
3. reduce active filter use cost;
4. Solve the defect of poor compensation effect of passive filtering.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
76
Year of Establishment
2002-06-24