| Customization: | Available |
|---|---|
| Nominal Voltage: | 832V |
| Warranty: | 1 Year to 5years |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Parameter | Specification |
| Product Model | LFEC-1000-2080 |
| DC Side Parameters | |
| Battery Cell Type (Ah) | LFP314 |
| Cluster Configuration | 1P260S × 5 clusters |
| Number of Clusters | 8 |
| Rated Voltage (V) | 832 |
| Voltage Range (V) | 728 - 923 |
| Rated Energy (kWh) | 2088 |
| Charge/Discharge Rate (P) | 0.5 |
| Cooling Method | Intelligent Liquid Cooling |
| AC Side Parameters | |
| Rated Charging/Discharging Power (kW) | 1000 |
| Max. Charging/Discharging Power (kW) | 1100 |
| Rated Charge/Discharge Current (A) | 1444 |
| Rated Grid Voltage (V) | 400 |
| Wiring Method | Three-phase four-wire |
| Grid Frequency Range (Hz) | 50 |
| THDi | < 3% (rated power) |
| Power Factor | > 0.99 |
| System Specifications | |
| Max. System Efficiency | > 90% |
| Cycle Life | 6000 cycles @ 25°C, 0.5C/0.5C, 90% DoD, 70% EOL |
| Dimensions (W×D×H) (mm) | 2438 × 6058 × 2896 (Customized as needed) |
| Weight (t) | 29 |
| Output Isolation | Optional |
| STS Fast Switching Module | Optional |
| Operating Temperature | -20°C ~ 55°C |
| Operating Humidity (RH) | 0% - 95% |
| Altitude (m) | ≤ 2000 |
| IP Rating | IP55 |
| Fire Protection | Pack-level fire suppression + cabin-level water spray |
| Communication Interface | RS485, Ethernet |
| Communication Protocol | Modbus RTU / Modbus TCP |
| Application | Description |
| Utility-Scale Storage | Grid frequency regulation, peak shaving, renewable firming |
| Large Industrial Microgrids | Primary power source for factories, mines, and industrial parks |
| Off-Grid & Emergency Backup | Seamless transition during power outages |
| Renewable Integration | AC/DC coupling for solar/wind + storage |
| Diesel Replacement | Solar + storage hybrid systems to reduce fuel consumption |
| Feature | LFEC-1000-2080 | LFEM-500-1566 |
| Container Size | 20 ft | 20 ft |
| Rated Power | 1000 kW | 500 kW |
| Rated Energy | 2088 kWh | 1566 kWh |
| AC/DC Integration | AC/DC integrated | DC-coupled microgrid |
| STS Module | Optional | Standard |
| Application | Large utility, grid-scale | Microgrid, industrial parks |
| Parameter | Value |
| Rated Active Power (kW) | 1000 |
| Rated Apparent Power (kVA) | ~1250 |
| Max. Active Power (kW) | 1100 |
| Max. Apparent Power (kVA) | ~1375 |
| Power Factor Range | >0.99 (adjustable) |
| AC Voltage | 400 V (three-phase four-wire) |
| Rated AC Current | 1444 A |
| Benefit | Description |
| Power Factor Correction | Reduce utility penalties for low power factor by locally supplying reactive power |
| Voltage Support | Stabilize grid voltage at the point of connection, especially in weak grids or long feeders |
| Reduced Line Losses | Minimize I²R losses by reducing reactive current flow in cables and transformers |
| Increased System Capacity | Free up capacity in transformers and cables by compensating reactive power locally |



BESS simulation test lab